Product Description
W&H WS-91 LG Surgical Contra Angle 1:2.7 Handpiece is an advanced dental tool tailored for surgical precision. Featuring a unique 45 head design, it combines the benefits of straight and contra-angle handpieces, significantly improving visibility during procedures such as wisdom teeth extraction and hemisection. With a dismantlable structure for easy maintenance, the handpiece operates at a 1:2.7 ratio, achieving speeds up to 135,000 revolutions per minute, ensuring efficiency in surgical tasks. Its mini LED+ enhances visibility, and the triple spray system guarantees ample cooling for both the rotary instrument and the tooth. The ISO 3964 coupling system ensures compatibility with various dental equipment. Offering versatility and simplifying access to molars, this handpiece stands out for its precision, adaptability, and cooling efficacy in dental surgical applications.
INDICATIONS:
- Hemisection
- Extraction of wisdom teeth
- Contra-angle design with 45 head.
- Dismantlable structure with ISO 3964 coupling.
- Performance: 1:2.7 ratio, 135,000 RPM, Mini LED+.
- Construction: Durable materials, precision engineering.
- Compatibility: FG shank 1.6 mm, ISO 3964 couplingPreparation:
- Ensure that the handpiece is clean, lubricated (if required), and in good condition.
- Confirm compatibility with your dental unit and the rotary instruments you plan to use.
Handpiece Connection:
- Connect the handpiece to the dental unit using the ISO 3964 coupling system.
- Secure the connection to prevent any wobbling during use.
Rotary Instrument Attachment:
- Choose a rotary instrument with an FG shank diameter of 1.6 mm.
- Insert the rotary instrument into the handpiece, making sure it is securely in place.
Water and Spray Adjustments:
- Adjust the water flow and spray settings on your dental unit according to the procedure.
- Confirm that the triple spray system is functioning properly to ensure adequate cooling.
Illumination Setup:
- If your handpiece has a Mini LED+ feature, activate it for improved visibility.
- Adjust the illumination intensity based on your preferences and the needs of the procedure.
Patient Preparation:
- Communicate with the patient, explaining the procedure and addressing any concerns.
- Ensure the patient is comfortable and the treatment area is properly isolated.
Procedure Execution:
- Start the dental procedure with the Surgical Contra Angle Handpiece.
- Utilize the 45 head for improved visibility and access, especially in challenging areas like molars.
- Maintain a steady hand, proper angulation, and controlled movements for precision.
Monitoring and Adjustments:
- Monitor the cooling system throughout the procedure to prevent overheating.
- Make any necessary adjustments to the handpiece settings, water flow, or illumination as needed.
Rotary Instrument Removal:
- After completing the procedure, carefully detach the rotary instrument from the handpiece.